Timer To Close
– Verify that the close limit is activated (LED On)
– Set selector switch to ‘Tm Cls’
– Press STOP to reset timer
– Press OPEN to add 15 second intervals (4 X is 60 seconds)
– Press CLOSE to add 1 second intervals (5 X is 5 seconds)
– Move selector switch to TS
Operator Modes
– C2: Momentary contact to open/stop door. Constant pressure to close door.
– B2: Momentary contact to open/close/stop door.
– TS: Momentary contact to open/close/stop door. Timer will close door automatically after timeout.
– D1: Constant pressure to open/close door.